Hybrid Battery Maintenance

I. Single Module 7.2V Maintenance Procedure:
Compatible With Car Model: Honda 1st Gen. Insight 2000-2006Honda 1st Gen. Civic 2003-2005Honda 1st Gen. Accord 2005-2007Toyota 1st Gen. Prius 1997-2000, etc.

If the delivery time from us to your address is about 1 month, please recharge the battery within 2 months (total time 3 months) after you receive it, then assemble the battery pack and send it to the terminal customer for usage.

The suggested maintenance procedure is as follows:

1. The module shall be charged at a constant current of 6A for 15 minutes (25% SOC), the voltage limitation setting is 9.0V, stop charging if the module voltage limitation >9.0V, the module temperature limitation (T the highest) ≤ 42℃ when charging.
2. Rest 5 minutes;
3. The module shall be charged at a constant current of 1.2A for 30 minutes (10% SOC), the voltage limitation setting is 9.0V, stop charging if the module voltage limitation >9.0V, the module temperature limitation (T the highest) ≤ 42℃ when charging.
4. Rest 30 minutes;
5. Then the module shall be discharged at a constant current of 6A for 5 minutes(8% SOC), the voltage limitation setting is 7.5V, stop discharging if the module voltage limitation<7.5V, the module temperature limitation (T the highest) ≤ 42℃ when discharging.

Note:
The temperature of a testing environment for the above operation is 25 ℃±5 ℃(Must be done under ventilated conditions); A whole battery pack must be finished and charged within one day or earlier.

Okacc Hybrid Batteries suggests you follow our maintenance steps above for every batch of batteries before delivery from your company. Please keep repeating them once the batteries are in stock every six months.

II. 14.4V Module Maintenance Procedure:
Compatible With Car Model: Honda 1st Gen. FITHonda 2nd Gen. Accord 2010-2012Honda 2nd Gen. Insight 2010-2012Honda CR-Z 2011-2012Honda 2nd Gen. Civic 2006-2011Toyota 2nd Gen.PRIUS 2004-2009Toyota 3rd Gen.Prius 2010-2014Lexus CT200hToyota PRIUS Aqua/Prius CToyota Camry xv40  6th 2007-2011Toyota Camry xv50  7th 2012-2016Lexus es300hLexus GS450hLexus IS300hLexus NX300h, etc.

If the delivery time from us to your address is about 1 month, please recharge the battery within 2 months (total time 3 months) after you receive it, then assemble the battery pack and send it to the terminal customer for usage.

The suggested maintenance procedure is as follows:

1. The module shall be charged at a constant current of 6A for 15 minutes (25% SOC), the voltage limitation setting is 18.0V, stop charging if the module voltage limitation >18.0V, the module temperature limitation (T the highest) ≤ 42℃ when charging.
2. Rest 5 minutes;
3. The module shall be charged at a constant current of 1.2A for 30 minutes (10% SOC), the voltage limitation setting is 18.0V, stop charging if the module voltage limitation >18.0V, the module temperature limitation (T the highest) ≤ 42℃ when charging.
4. Rest 30 minutes;
5. Then the module shall be discharged at a constant current of 6A for 5 minutes(8% SOC), the voltage limitation setting is 15.0V, stop discharging if the module voltage limitation <15.0V, the module temperature limitation (T the highest) ≤ 42℃ when discharging.

Note: The temperature of a testing environment for the above operation is 25 ℃±5 ℃(Must be done under ventilated conditions); A whole battery pack must be finished and charged within one day or earlier.

Okacc Hybrid Batteries suggests you follow our maintenance steps above for every batch of batteries before delivery from your company. Please keep repeating them once the batteries are in stock every six months.

III. 19.2V Module Maintenance Procedure
Compatible With Car Model: Lexus RX400hToyota Highlander 2006-2009Lexus RX450h, etc.

If the delivery time from us to your address is about 1 month, please recharge the battery within 2 months (total time 3 months) after you receive it, then assemble the battery pack and send it to the terminal customer for usage.

The suggested maintenance procedure is as follows:

1. The module shall be charged at a constant current of 6A for 15 minutes (25% SOC), the voltage limitation setting is 24.0V, stop charging if the module voltage limitation >24.0V, the module temperature limitation (T the highest) ≤ 42℃ when charging;
2.  Rest 5 minutes;
3. The module shall be charged at a constant current of 1.2A for 30 minutes (10% SOC), the voltage limitation setting is 24.0V, stop charging if the module voltage limitation >24.0V, the module temperature limitation (T the highest) ≤ 42℃ when charging;
4. Rest 30 minutes;
5. Then the module shall be discharged at a constant current of 6A for 5 minutes(8% SOC), the voltage limitation setting is 20.0V, stop discharging if the module voltage limitation<20.0V, the module temperature limitation (T the highest) ≤ 42℃ when discharging;

Note: The temperature of a testing environment for the above operation is 25 ℃±5 ℃(Must be done under ventilated conditions); A whole battery pack must be finished and charged within one day or earlier.

Okacc Hybrid Batteries suggests you follow our maintenance steps above for every batch of batteries before delivery from your company. Please keep repeating them once the batteries are in stock every six months.

2) When there is no charging and discharging equipment, we recommend at least charging according to the following requirements, which are suitable for individual users or small dealers.

I. Single Stick 7.2V Maintenance Procedure
Compatible With Car Model: Honda 1st Gen. Insight 2000-2006Honda 1st Gen. Civic 2003-2005Honda 1st Gen. Accord 2005-2007Toyota 1st Gen. Prius 1997-2000, etc.

If the delivery time from us to your address is about 1 month, please recharge the battery within 2 months (total time 3 months) after you receive it, then assemble the battery pack and send it to the terminal customer for usage.

The suggested maintenance procedure is as follows:

The module shall be charged at a constant current of 6A for 15 minutes (25% SOC), the voltage limitation setting is 9.0V, stop charging if the module voltage limitation >9.0V, and the module temperature limitation (T the highest) ≤ 42℃ when charging.

Note: The temperature of a testing environment for the above operation is 25 ℃±5 ℃(Must be done under ventilated conditions); A whole battery pack must be finished and charged within one day or earlier.

Okacc Hybrid Batteries suggests you follow our maintenance steps above for every batch of batteries before delivery from your company. Please keep repeating them once the batteries are in stock every six months.

II. 14.4V Module Maintenance Procedure
Compatible With Car Model: Honda 1st Gen. FITHonda 2nd Gen. Accord 2010-2012Honda 2nd Gen. Insight 2010-2012Honda CR-Z 2011-2012Honda 2nd Gen. Civic 2006-2011Toyota 2nd Gen.PRIUS 2004-2009Toyota 3rd Gen.Prius 2010-2014Lexus CT200hToyota PRIUS Aqua/Prius CToyota Camry xv40  6th 2007-2011Toyota Camry xv50  7th 2012-2016Lexus es300hLexus GS450hLexus IS300hLexus NX300h, etc.

If the delivery time from us to your address is about 1 month, please recharge the battery within 2 months (total time 3 months) after you receive it, then assemble the battery pack and send it to the terminal customer for usage.

The suggested maintenance procedure is as follows:

The module shall be charged at a constant current of 6A for 15 minutes (25% SOC), the voltage limitation setting is 18.0V, stop charging if the module voltage limitation >18.0V, and the module temperature limitation (T the highest) ≤ 42℃ when charging.

Note: The temperature of a testing environment for the above operation is 25 ℃±5 ℃(Must be done under ventilated conditions); A whole battery pack must be finished and charged within one day or earlier.

Okacc Hybrid Batteries suggests you follow our maintenance steps above for every batch of batteries before delivery from your company. Please keep repeating them once the batteries are in stock every six months.

III. 19.2V Module Maintenance Procedure
Compatible With Car Model: Lexus RX400hToyota Highlander 2006-2009Lexus RX450h, etc.

If the delivery time from us to your address is about 1 month, please recharge the battery within 2 months (total time 3 months) after you receive it, then assemble the battery pack and send it to the terminal customer for usage.

The suggested maintenance procedure is as follows:

The module shall be charged at a constant current of 6A for 15 minutes (25% SOC), the voltage limitation setting is 24.0V, stop charging if the module voltage limitation >24.0V, the module temperature limitation (T the highest) ≤ 42℃ when charging;

Note: The temperature of a testing environment for the above operation is 25 ℃±5 ℃(Must be done under ventilated conditions); A whole battery pack must be finished and charged within one day or earlier.

Okacc Hybrid Batteries suggests you follow our maintenance steps above for every batch of batteries before delivery from your company. Please keep repeating them once the batteries are in stock every six months.

Experienced Over 15 Years
Let our honest and dedicated 15-year journey in hybrid battery manufacturing provide you with safe, sustainable energy.
Reliable Performance
Rely on Okacc hybrid batteries for consistent, reliable performance that meets and exceeds your energy expectations.
Mature Technology
Experience our mature technology and join us in powering a trusted, energy-efficient future for all.
China Factory Price
Rely on our factory price advantage to secure superior hybrid battery solutions for your business.